Chemistry Serum Plasma Urine Centrifuge

Chemistry Serum Plasma Urine Centrifuge

TD5ADesktop Low Speed CentrifugeIntroduction:It is used for animal and plant molecular biology, microorganisms, nu
Send Inquiry

TD5A Desktop Low Speed Centrifuge


Introduction:

It is used for animal and plant molecular biology, microorganisms, nucleic acid extraction, cell separation, and clinical testing samples. It is suitable for medical, life sciences, agricultural sciences, environmental testing, and other scientific research institutions.


Features:

 Microcomputer precise control, frequency conversion motor drive, 5-inch touch display, simultaneous display of rotation speed, running time, lifting speed gear.

It can view operation records and fault records in real time, and the external USB interface of the fuselage can export data in real time to ensure the integrity of the data.

 The ladder runtime program can be edited, the RCF value is automatically calculated, the program can be edited and saved, and the user can adjust it according to the needs.

 Ado

pt all-steel structure, built-in explosion-proof inner sleeve, special shock absorber, multi-layer shock absorption, improve the stability of the machine and reduce noise.

 Induction electric suction door lock, with emergency unlocking function, overspeed, overload, door cover detection protection and other functions.

 A variety of rotors with different capacities can be selected to meet the needs of different fields and experiments.

 Manual program locking function, also with rotor automatic recognition function.

 Built-in ventilation duct to effectively prevent the temperature in the centrifugal chamber from rising too high.


Specification:

Maximum speed

 6000r/min

Maximum capacity

 4x300ml

Maximum relative centrifugal force

 4750xg

Timing range

 1min~99h59min

Net weight

 55kg

Noise of the whole machine

 ≤ 60dB

Centrifugal chamber diameter

 Ф400mm

Power & Power

 AC 220V/50Hz/0.75kW

Speed accuracy

 ±20/min

Temperature control accuracy

 ±1°C

Dimensions

620x460x360


TD5A Adapted Rotor:

Numbering

Rotor type

Capacity(ml)

Maximum speed(r/min)

Maximum relative centrifugal force

RCFxg

NO0701

Horizontal rotor

4x50ml

5000r/min

4750xg

NO0702

Horizontal rotor

4x100ml

5000r/min

4750xg

NO0703

Horizontal rotor

4x2x50ml

4000r/min

3280xg

NO0720

Horizontal rotor

4x8x15ml

4000r/min

3280xg

NO0704

Horizontal rotor

4x2x100ml

4000r/min

3050xg

NO0706-1

Horizontal rotor

4x24x7/5ml blood-collecting vessel

4000r/min

2950xg

NO0707

Horizontal rotor

4x300ml(250ml centrifuge bottle)

4000r/min

3100xg

NO0707-4

Horizontal rotor

4x18x7/5ml Automatic hat removal

4000r/min

2980xg

NO0722

Horizontal rotor

2x3x96 well ELISA plate

4000r/min

2350xg

NO0776

Angular rotor

6x50ml

6000r/min

4150xg

NO0777

Angular rotor

8x50ml

6000r/min

4550xg

NO0778

Angular rotor

6x100ml

6000r/min

4550xg

NO0779

Angular rotor

12x15ml

6000r/min

4450xg

NO0780

Angular rotor

24x15ml

4000r/min

3550xg

PRP

Horizontal rotor

4x50ml Syringe

4000r/min

3200xg

CGF1-4

Horizontal rotor

4x50ml Syringe

4-step fixed ladder program

11-14

Horizontal rotor

                       4-step adjustable ladder program