BOD-573 biochemical oxygen demand meter

BOD-573 biochemical oxygen demand meter

BOD (biochemical oxygen demand) refers to the amount of dissolved oxygen consumed by microorganisms to decompose biodegradable organic matter in water under certain conditions. It is a comprehensive indicator reflecting the content of organic pollutants i
Send Inquiry

BOD-573 BOD

BOD COD.png 

 

Brief Introduction:

The BOD biochemical oxygen demand meter is based on the national standard "HJ 505-2009 5-day culture method", which simulates the biodegradation process of organic matter in nature, and uses a simple, safe and reliable mercury-free pressure difference sensing method to measure BOD in water. Fully intelligent R&D process, design and manufacturing. No experimental personnel are required to be on duty during the experiment. It is suitable for environmental monitoring stations, sewage treatment plants, third-party testing agencies, food factories, scientific research universities and other units.

 

Features:

Use mercury-free pressure difference sensing method to test the BOD concentration in water;

Integrated high-precision air pressure sensing device, replacing the traditional mercury column manometry method, improving operational safety and measurement accuracy and sensitivity;

Six independent test terminals, new measurement groups can be added at any time during the testing process, and six samples can be measured simultaneously;

The measurement range is selectable, and when the water sample concentration is lower than 4000g/L, no dilution is required;

The sample culture time can be selected and set from 1 day to 30 days according to needs;

The test data does not need to be converted, and the test results can be automatically displayed and stored;

Automatically save process data and view process data. Can store BOD test data for 10 years;

Support viewing and deletion of historical measurement data;

With temperature compensation delay setting function, automatic operation will start after the sample temperature reaches the culture constant temperature;

The test terminal comes with a large-capacity battery with a battery life of more than 2 years. During the test, it is not affected by short-term power outages in the external environment;

Complete the measurement process automatically without supervision. The system will automatically shut down after the measurement is completed.

 

Technical parameters:

 

Measuring range

BOD  0-4000mg/L(8 ranges)

Measurement days

1-30 days

Measurement principle

Mercury-free differential pressure method

Measurement period

1-7 days

Measurement accuracy

±8%

Measure quantity

1-6 pieces

Measurement error

Comply with water quality BOD5 accuracy test standard

(glucose-glutamic acid standard BOD5=180-230mg/l)

Culture temperature

20±1℃

Culture bottle volume

580ml

Stirring speed

Program control, magnetic stirring

Working power supply

AC220V±10%/50Hz/30W

data storage

10 years

Dimensions

292×200×318mm

Host weight

2.7kg